Description
Features:
100MHz bandwidths.
1GSa/s Real Time sample rate.
Large (7.0-inch) color display, WVGA(800x480).
Record length up to 40K.
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard.
Multiple automatic measurements.
Four math functions, including FFTs standard.
Provides software for PC real-time analysis.
Specifications:
Size: 14 x 11x 32cm/5.51 x 4.33 x 12.60inch
Weight: 2900g
Model
DSO5102P
Acquisition
Sample Rate
Real-Time Sample: 1GS/s
Equivalent Sample: 25GS/S
Acquisition Modes
Normal
Normal data only
Peak Detect
High-frequency and random glith capture
Average
Waveform Average, selectable 4.8.16.32,64,128
Inputs
Inputs Coupling
AC, DC. GND
Inputs Impedance
1MΩ±2%ll20pF±3pF
Probe Attenuation
1X,10X
Supported Probe Attenuation Factor
1X,10X,100X,1000X
Maximum Input Voltage
CAT I and CAT II: 300VRMS (10x), Installation Category;
CAT III: 150VRMS(1x);
Installation Category II: derate at20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range
500MS/S - 1GS/S
Waveform Interpolation
(sin x)/x
Record Length
40K
SEC/DIV Range
Sample Rate and Delay Time Accuracy
±50ppm (at over any ≥1ms time interval)
Position Range
20ns/div to 80us/div; (-8divx s/div) to 40ms;
200us/div to 40s/div; (-8divx s/div) to 400s
Delta Time Measurement
Accuracy
(Full Bandwidth)
Single-shot. Normal mode:± (1 sample interval +100ppm x reading + 0.6ns); >16 averages:
(1 sample interval + 100ppm x reading + 0.4ns);
Sample interval = s/div / 200
Vertical
Vertical Resolution
8-bit resolution, all channel sampled simultaneously
Position Range
2mV/div to 200mV/div, ±2V 200mV/div to 5V/div, ±50V
Bandwidth
100MHz
Rise Time at BNC( typical)
3.5ns
Analog Bandwidth in Normal and Average modes at BNC or with probe. DC Coupled
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div,±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math
+, - ,x, /, FFT
FFT
Windows: Hanning. Flatop. Rectamgular, Bartlett. Blackman; 1024 sample point
Bandwidth Limit
20MHz
Low Frequency Response (-3db)
≤10Hz at BNC
DC Gain Accuracy
±3%for Normal or Average acquisition mode. 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode. 5mV/div to 2mV/div
DC Measurement Accuracy, Average Acquisition Mode
When vertical displacement is zero, and N s16:± (3% x reading + 0.1div+ 1mV)only 10mV/div or greater is selected;
When vertical displacement is not zero, and Ns16: ± (3% x (reading + vertical position) +1% of vertical position + 0.2div); Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, Average Acquisition Mode
Delta volts between any two averages of si 6 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types
Edge. Video. Pulse. Slope. Overtime. Alternative
Trigger Source
CH1f CH2, EXT, EXT/5, AC Line
Trigger Modes
Auto, Normal, Single
Coupling Type
DC, AC, Noise Reject, HF Reject. LF Reject
Trigger Sensitivity (Edge Trigger Type)
DC(CH1.CH2):
1 div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT):
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):
1Vfrom DC to 100MHz; 1.75V from 100MHz to 200MHz;
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range
CH1/CH2: ±8 divisions from center of screen; EXT:±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns
CH1/CH2:0.2div x volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical)
Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type
CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5:2V
Signal Formats and Field Rates. Video Trigger Type
Supports NTSC, PAL and SECAM broadcast systems for any field or any line</
-
Fruugo ID:
334015551-736241209
-
EAN:
7695727303843
Product Safety Information
Please see the product safety information specific to this product outlined below
The following information is provided by the independent third-party retailer selling this product.
Product Safety Labels
Safety Warnings:
Warning: Please read the product instructions carefully before use to ensure correct use.
Serial Number:
7695727303843
Delivery & Returns
Dispatched within 2 days
Shipping from China.
We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy